This Article is written as a recommendation for you. Every article is checked by a technical specialist. Please be informed that as of a high count of articles not all are checked direct after publication. If you have any feedback regarding our articles, please don't hesitate to contact us via DE_LEJ_GSD_DTCG(at)Dell.com .


Please Note before Update:

- Do a backup of your data!
- The update-process could take up to 30 minutes and both controller will be restarted.
- For the update the storage have to be in the optimal-state.
- We recommend to do the Update in a Downtime, cause the IO will be stopped during the update.
- Please check the compatibility-guide of your software-/OS-vendor if the Firmware is approved.


This manual describe how to update from the firmware-version 07.80.41.60 or lower.

  1. Please download the needed Firmware and Ressource-DVD.

    1. Ressource-CD/DVD: MD32x0 [Build 6.4.0.5] Download
    2. Firmware: 
      • MD3200/MD3220 (SAS) [08.20.20.60] Download
      • MD3200i/MD3220i (iSCSI) [08.20.20.60] Download
      • MD3260 (SAS) [08.20.20.60] Download
      • MD3260i (iSCSI) [08.20.20.60] Download
      • MD3600i/MD3620i (iSCSI) [08.20.20.60] Download
      • MD3600f/MD3620f (Fibrechannel) [08.20.20.60] Download

  2. Install the newest Ressource-CD/DVD.
    Please uninstall the older Version of the Modular Disk Storage Manager before you begin. Please be aware that it automaticly uninstall the Multipathdriver.

    1. Full Installation - includes the MDSM and the multipathdriver (for server with storage-access and management)

    2. Host Installation - includes only the multipathdriver (for Server with storage-access but no management)

    3. Management Station - includes only the MDSM (for server/client with management only)

  3. Extract the controller-firmware (from 1b).

  4. Update the firmware as follows:

    1. Open the Modular Disk Storage Manager (MDSM) and connect to the storage you want to update.
    2. Choose the tab Support.
    3. Choose in there the item Download Firmware and in the appearing window Browse to choose the firmwareupdate.
    4. After that a Window occure, where you have to choose Download RAID Controller Module Firmware.
      The update utility will check now the Major Event Log for actually existing issues. If there are failure-entries you will get a message. In this Case save and clear the MEL and the update will run.
    5. For the RAID-Controller-Firmware please choose the file with the ending *.dlp. Additionaly, please select the check-box Transfer NVSRAM with Raid controller module Firmware and provide the path to the NVSRAM-file via Browse.
      If the Firmwareversion 07.75.28.60 is not installed please update to this Version first.

    6. Please start the update by clicking Transfere
      This process can be take up to 30 Minutes.

    7. Also update the firmware of the harddrives after the controller update finished fine.

        1. Download the HDD-Firmware [Vers.A27] (Downloadand extract the file.
        2. Start the Modular Disk Storage Manager (MDSM).

        1. Choose the menue Upgrade.
        2. Now choose Physical Disk Firmware.
        3. In the window, which now appears please click Next.
        4. Now you will find the information which firmware-packages are installed in the moment for the physical drives.
        5. Now please open the ReadMe.txt, which is located in the extracted folder.
        6. In that file you can search for the shown Firmware and you will find the actual package according this firmware.

        1. If you use Add... you can attach the needed update from the folder.
        2. Than you can also add additional packages for the different HDD-types by clicking Add... again.
        3. Please now click Next.
        4. In the following window you will see a survey with the compatible HDD. Please select the box Select All and click the Finish-button. Now all updates will be enforced to the drives.